SQCpack Tech Tuesday Series

(Originally presented August 2019)

A series of 15-minute webinars designed to help customers explore specific features in SQCpack, discover best practices, and realize new levels of value from your SQCpack investment.

Part 1 – Safeguarding Your Data: Discover best practices for configuring user roles and auditing to ensure the safety of your essential quality data.

View Recording

Part 2 – Managing Specifications:
Adhering to customer specifications is a critical part of your quality system. Our experts will show you how to optimize key features in SQCpack to make managing and communicating your specifications a breeze.

View Recording

Part 3 – Importing and Linking Data:
You’ll learn the distinction between importing from and linking to external data sources to get the most value from SQCpack.

View Recording

Part 4 – Creating Certificates of Analysis:
Learn how to create a custom branded Certificate of Analysis template that will communicate your SQCpack quality outcomes while impressing your customers.

View Recording
 

MartyVSPC

Starting to get Involved
Hey there, I have a question about how SQC pack calculates control limits (it came up in a recent audit). I just attempted to calculate Cp and Cpk manually and compare it to one of our charts on SQC pack. I get the same value for the mean and standard deviation as SQC pack does, however I get slightly different values for the upper and lower control limits. I was taught to calculate these by adding/subtracting 3 standard deviations from the mean value. It does not appear SQC pack does this in exactly the same way. I'm curious if anyone can explain what SQC pack does differently when calculating these values.
 